Product

ESR rack, suitable for S-Monovette®

Order number: 90.1060.062
ESR rack, suitable for S-Monovette®

Product description

Order number 90.1060.062
Product description ESR rack, suitable for S-Monovette®, without back panel

Product characteristics

Design without back panel
Suitable for S-Monovette®

Purity & certification

Product category In vitrodiagnostic device, CE
CE certified CE
Batched yes

Packaging

Minimum order qty. 1
Piece(s) / inner box 1
Piece (s) / outer case 20
Piece(s) / pallet 1560
Depth of case 428 mm
Width of case 323 mm
Height of case 130 mm
Case volume 0.018 cbm
Weight of product 1.167 kg
Weight of case 23.8 kg
EAN of inner box 4038917124935
EAN case 4038917019545
Product specification

General

  • +

    Can the Sediplus® S 2000 NX ESR analyser be integrated into an existing LIS system?

    Yes, the Sediplus® S 2000 NX can be integrated through an interface.

  • +

    Do all the S-Sedivettes have to be placed in the Sediplus® device at the same time?

    No, each measuring station can be filled individually / independently of time.

  • +

    Is there an option to automatically determine ESR?

    Yes, the ESR can be determined automatically with the Sediplus® S 2000 NX (40 measuring stations).

  • +

    What must be taken into account when using the S-Sedivette® for blood sedimentation?

    For blood sedimentation, the S-Sedivette® should always be carefully mixed after blood collection. According to the CLSI standard, the measurement must be started no later than 4 hours after blood collection. The first reading of the blood sedimentation rate (ESR) should take place after 60 minutes. 

  • +

    How is the S-Sedivette® prepared?

    The S-Sedivette® is prepared with trisodium citrate solution, which is 20% of the nominal volume. This ensures the important ratio for blood sedimentation of 1 part citrate + 4 parts blood.

  • +

    What is the shelf life of the S-Sedivette®?

    The S-Sedivette® has a shelf life of 15 months.

  • +

    Does the S-Sedivette® have to be mixed after blood collection?

    Yes, the S-Sedivette® must be mixed thoroughly immediately after blood collection: invert the S-Sedivette® slowly five times. The air bubble / glass bead must always travel to the other end. Do not shake it back and forth quickly. For safety and to save time, we recommend the special Sarmix® M 2000 mixers.

  • +

    Are the values from the S-Sedivette® comparable to the Westergren method?

    The S-Sedivette® was developed and evaluated for determining the blood sedimentation rate (ESR) according to the Westergren method.