Sediplus® System Solutions
Sediplus® System Solutions
Language:
Order number | 18.1325 |
---|---|
Product description | Microvette® CB 200 NC, capillary blood collection, preparation: Trisodium citrate solution (1:4), nominal volume: 200 µl, (LxØ) with cap: 46 x 10.8 mm, cap violet, push cap, flat base, incl. sedimentation pipette, 50 piece(s)/bag |
Type of collection | capillary |
---|---|
Type of preparation | Trisodium citrate solution (1:4) |
Colour code | EU |
Closure type | push cap |
Application | capillary blood collection |
Base shape | flat base |
Sample volume | 200 µl |
---|---|
Diameter | 10.8 mm |
Length of product | 40 mm |
Length including cap | 46 mm |
Length excluding cap | 40 mm |
Product material | Polypropylene (PP) |
---|---|
Colour of product | transparent |
Closure material | Low Density Polyethylene (LD-PE) |
Colour of cap | violet |
Product category | In vitrodiagnostic device, CE |
---|---|
CE certified | CE |
Batched | yes |
Minimum order qty. | 500 |
---|---|
Type of smallest subpackaging | bag |
Piece(s) / inner box | 50 |
Piece (s) / outer case | 500 |
Piece(s) / pallet | 32000 |
Depth of box | 271 mm |
Width of box | 126 mm |
Height of box | 36 mm |
Depth of case | 283 mm |
Width of case | 268 mm |
Height of case | 210 mm |
Case volume | 0.0159 cbm |
Weight of product | 0.0036 kg |
Weight of case | 2.6 kg |
EAN of inner box | 4038917086202 |
EAN case | 4038917004787 |
Yes, the Sediplus® S 2000 NX can be integrated through an interface.
No, each measuring station can be filled individually / independently of time.
Yes, the ESR can be determined automatically with the Sediplus® S 2000 NX (40 measuring stations).
For blood sedimentation, the S-Sedivette® should always be carefully mixed after blood collection. According to the CLSI standard, the measurement must be started no later than 4 hours after blood collection. The first reading of the blood sedimentation rate (ESR) should take place after 60 minutes.
The S-Sedivette® is prepared with trisodium citrate solution, which is 20% of the nominal volume. This ensures the important ratio for blood sedimentation of 1 part citrate + 4 parts blood.
The S-Sedivette® has a shelf life of 15 months.
Yes, the S-Sedivette® must be mixed thoroughly immediately after blood collection: invert the S-Sedivette® slowly five times. The air bubble / glass bead must always travel to the other end. Do not shake it back and forth quickly. For safety and to save time, we recommend the special Sarmix® M 2000 mixers.
The S-Sedivette® was developed and evaluated for determining the blood sedimentation rate (ESR) according to the Westergren method.