Product

Base station, PC, suitable for work tray 95.987.002 & 0.2 ml PCR tubes

Order number: 95.988.002
Base station, PC, suitable for work tray 95.987.002 & 0.2 ml PCR tubes

Product description

Order number 95.988.002
Product description Base station, material: PC, blue, (LxWxH): 128 x 85.5 x 30.4 mm, suitable for work tray 95.987.002 & 0.2 ml PCR tubes, 5 piece(s)/case

Product characteristics

Suitable for work tray 95.987.002 & 0.2 ml PCR tubes

Size

Width of product 85.5 mm
Height of product 30.4 mm
Length of product 128 mm

Material & colours

Product material Polycarbonate (PC)
Colour of product blue

Purity & certification

Product category no medical device | IVD
Batched no

Packaging

Minimum order qty. 5
Type of smallest subpackaging case
Piece(s) / inner box 5
Piece (s) / outer case 75
Piece(s) / pallet 3600
Depth of case 598 mm
Width of case 398 mm
Height of case 145 mm
Case volume 0.0345 cbm
Weight of product 0.0302 kg
Weight of case 2.83 kg
EAN of inner box 4038917124171
EAN case 4038917019132
Product specification
NGS Library Preparation

NGS Library Preparation

PCR & Molecular biology

PCR & Molecular biology

General

  • +

    With which cyclers are our PCR plates compatible?

    The following table lists the compatibilities of all common cyclers with our range of PCR plates.

  • +

    Why should 'PCR Performance Tested' certified Multiply® PCR tubes and plates not be autoclaved?

    In principle, it is possible to autoclave our PCR tubes and PCR plates without affecting the material properties as they are made of polypropylene. However, all Multiply® PCR tubes and PCR plates produced by Sarstedt are manufactured under cleanroom conditions and are free from DNases/RNases, DNA and PCR inhibitors ('PCR Performance Tested'). This means that the most important parameters for a reliable PCR result are present in advance and our PCR tubes and PCR plates can be used for PCR reactions directly. We therefore recommend that you do not autoclave 'PCR Performance Tested' certified PCR tubes and plates because, contrary to the intention of this step, it results in a risk of contaminating the materials with nucleic acids. 

  • +

    What is the difference between plates with 'high-profile' and 'low-profile' well design?

    Low-profile PCR plates and PCR tubes have a low height, minimising the dead volume in the individual wells compared to high-profile products. Therefore the volume of reagents used can be reduced significantly, effectively reducing costs.

  • +

    When should a white PCR plate be used?

    If there is only very minimal starting material and therefore a correspondingly low concentration of cDNA is available. 

    The optimised reflection properties of the wells of white Multiply® PCR plates effectively prevent 'crosstalk' between the wells and increase the fluorescence level of the qPCR reaction by a factor of 10. In this way, reliable Ct values can still be generated through the common qPCR cycles even when there is only a small volume of starting material.

    If you are aiming to achieve the lowest possible variability. 

    The optimised reflection properties of the white Multiply® PCR plates ensure an even and stable fluorescence level of the qPCR reaction. This leads to a significantly improved reproducibility of the measurement results and increased accuracy. Tip: In order to further improve the variability, we recommend processing at least the template DNA and better still all of the reagents used, with our low retention pipette tips. 

    If you are aiming to save reagents. 

    The optimised reflection properties of the wells of white Multiply® PCR plates increase the fluorescence level of the qPCR reaction by a factor of 10. This means that the volume of reagents used can be reduced significantly, effectively reducing costs. 

  • +

    Can our Multiply® PCR tubes and Multiply® PCR plates be frozen or stored in cold storage rooms?

     

    In principle, Multiply® PCR tubes and Multiply® PCR plates can be frozen as they are made of polypropylene. However, the freezing conditions must be selected such that the content can be evenly frozen or frozen from the bottom to the top. Cracks caused by strain can occur in the lower part if the upper part of the tube freezes first as a result of unfavourable freezing conditions. For example, depending on the diameter of the hole, stands made out of Styrofoam have a strongly insulating effect which makes it more difficult to ensure the even freezing of the samples. Due to the large number of possible influence factors (the load on the tubes can be very different depending on the medium to be frozen and the routine conditions), we recommend you carry out a freezing test under your routine conditions. 

  • +

    Which lids and foils can be used for qPCR?

    We offer special transparent lid strips (65.1998.400) and a selection of transparent foils (95.1994, 95.1999) for qPCR. Items with frosted lids in the PCR strips offer the advantage of improved labelling and are suitable for standard PCR applications.  

Go to top