Product

Urine container, 3 l, with inspection strip and enclosed label with instructions for use, brown, with light protection, graduated

Order number: 77.575.001
Urine container, 3 l, with inspection strip and enclosed label with instructions for use, brown, with light protection, graduated

Product description

Order number 77.575.001
Product description Urine container, Urine collection, max. working volume: 3 l, Ø opening: 83.5 mm, brown, with light protection, graduated, material: PE, with paper label, english, cap: yellow, with inspection strip and enclosed label with instructions for use, 30 piece(s)/case

Product characteristics

Label/ Print with paper label
Graduation yes
Closure type screw cap
Light protection yes
Design with inspection strip and enclosed label with instructions for use
Application Urine collection
Viewing window yes

Size

Sample volume 3.000.00 ml
Max. volume 3 l
Diameter of opening 83,5 mm
Width of product 130 mm
Length of product 125 mm
Length including cap 246 mm
Length excluding cap 243 mm

Material & colours

Product material Polyethylene (PE)
Colour of product brown
Closure material Polypropylene (PP)
Colour of cap yellow

Purity & certification

Product category In vitrodiagnostic device, CE
CE certified CE
Safety data sheet no
Batched yes

Packaging

Minimum order qty. 30
Type of smallest subpackaging case
Piece(s) / inner box 30
Piece (s) / outer case 30
Piece(s) / pallet 270
Depth of case 643 mm
Width of case 403 mm
Height of case 515 mm
Case volume 0.1335 cbm
Weight of product 0.1136 kg
Weight of case 4.21 kg
EAN of inner box 4038917266222
EAN case 4038917266215
Product specification

You didn't find an answer to your question? Please contact us.

General

  • +

    Why should the 3 litre container be used?

    The 3 litre container is usually large enough for the 24-hours urine collection for more than 90 % of patients. The 2 litre container is usually suitable for 60 % of patients.

  • +

    What is the purpose of the clear strip on the 3 litre urine container?

    The clear strip is used as a viewing window with a scale to easily and accurately determine the collection amount. The 3 litre container and the UriSet 24 can therefore be hygienically and easily read from the outside.

  • +

    What is stabilised in the UriSet 24 with hydrochloric acid and for how long?

    Catecholamine, metanephrine, vanillylmandelic acid, homovanillic acid and 5-hydroxyindoleacetic acid are optimally stabilised by hydrochloric acid for up to 7 days.

  • +

    Which stabiliser is used in the UriSet 24?

    The stabiliser in the UriSet 24 is 20% hydrochloric acid (9 ml).

  • +

    Is the UriSet 24 suitable for transportation?

    After collecting the sample and establishing the volume collected, the urine can be transferred to a Urine Monovette® or transport tube. These sample tubes included in the complete set enable sample transport in accordance with P650 and also increase sample stability through light protection.

  • +

    What is the volume of the urine cup with integrated transfer device?

    The urine cup with integrated transfer device can contain 100 ml.

  • +

    Are the collection containers resistant to acids and alkalis?

    The urine collection containers are made of polyethylene (PE). PE has a high resistance to chemicals. Diluted acids, alkalis, alcohol, oil and water and saline solutions do not affect PE. Concentrated, oxidising acids, such as nitric acid and halogens, have a corrosive effect.

Go to top

Pre-analytics

  • +

    What is mid-stream urine?

    After cleaning the external genitalia and after urinating for approximately 3 seconds, about 10–20 ml of urine is collected in a sterile container without interrupting the urine stream. Impurities are avoided in this way. Once the designated sample volume has been collected, the remaining urine can be released into the lavatory.

  • +

    What type of analyses require mid-stream urine?

    Mid-stream urine is particularly important for microbiological tests.

  • +

    Why is 24-hour urine collected?

    24-hour urine collection eliminates concentration fluctuations occurring throughout the day. It is therefore suitable for safely and reliably determining parameters which are subject to concentration fluctuations (circardian rhythm), such as catecholamine or creatinine clearance.

  • +

    What should be considered when collecting 24-hour urine?

    Collecting 24-hour urine starts by emptying the bladder in the lavatory. This time must be noted (e.g. 7 a.m.). 

    The next bladder emptying must be transferred to the collection container and, if necessary, the stabiliser is added (do not forget to mix). 

    Each subsequent urination must be collected until the following day. The collection stops from the time that was noted on the previous day (e.g. 7 a.m.). The bladder should be emptied shortly before in order to add this sample to the amount collected.

Go to top

We would like to show you additional content which is hosted by a third party. For this purpose we need your consent to set cookies:

Patient information for 24-hour urine collection using a urine collection container NFT

Patient information for 24-hour urine collection using a urine collection container NFT

Patient information for 24-hour urine collection using a urine collection container NFT

X
Language:
SARSTEDT V-Monovette® Urine, urine cup and collection container with integrated transfer unit and accessories

SARSTEDT V-Monovette® Urine, urine cup and collection container with integrated transfer unit and accessories

SARSTEDT V-Monovette® Urine, urine cup and collection container with integrated transfer unit and accessories

X
Downloads: