Product

Microvette® 200 EDTA K3E, 200 µl, cap red, flat base

Order number: 20.1288
Microvette® 200 EDTA K3E, 200 µl, cap red, flat base

Product description

Order number 20.1288
Product description Microvette® 200 EDTA K3E, capillary blood collection, preparation: K3 EDTA, nominal volume: 200 µl, (LxØ) with cap: 47.6 x 10.8 mm, with print, cap red, flat base, inner receptacle: cylindrical, 100 piece(s)/case

Product characteristics

Type of collection capillary
Type of preparation K3 EDTA
Colour code EU
Label/ Print with print
Colour of print/label red
Cap cap
Application capillary blood collection
Base shape flat base
Shape of inner tube cylindrical

Size

Sample volume 200 µl
Diameter 10.8 mm
Length including cap 47.6 mm
Length excluding cap 46.6 mm

Material & colours

Product material Polypropylene (PP)
Colour of product transparent
Closure material High Density Polyethylene (HD-PE)
Colour of cap red

Purity & certification

Product category In-vitro diagnostic, CE
CE certified CE
Batched yes

Packaging

Minimum order qty. 1000
Type of smallest subpackaging case
Piece(s) / inner box 100
Piece (s) / outer case 1000
Piece(s) / pallet 121000
Depth of box 139 mm
Width of box 108 mm
Height of box 66 mm
Depth of case 338 mm
Width of case 228 mm
Height of case 160 mm
Case volume 0.0123 cbm
Weight of product 0.0028 kg
Weight of case 3.26 kg
EAN of inner box 4038917086028
EAN case 4038917070348
Product specification
Microvette® APT Automated Processing Tube

Microvette® APT Automated Processing Tube

Blood collection systems for paediatrics

Blood collection systems for paediatrics

Blood Collection Systems

Blood Collection Systems

Ordering Information Blood Collection Systems

Ordering Information Blood Collection Systems

General

  • +

    When should the Minivette® POCT be used?

    The Minivette® POCT is particularly suitable for the precise recovery and dispensing of defined small whole blood samples. This is especially required for Point-of-Care tests (POCT).

  • +

    Why does the Multivette® have two marks, and which one is the filling level mark?

    Both marks refer to the filling level. As the Multivette® is held horizontally and tilted slightly while collecting blood, the mark at the bottom of the Multivette® shows the correct filling level. After collection, the capillary tube is emptied through extraction. The filling level of an upright Multivette® can be read by the upper mark.

  • +

    Is the Multivette® suitable for venous or capillary blood collection?

    Both collection methods are possible with the Multivette®. The capillary tube has been developed so that either capillary blood can be collected directly with the self-filling capillary tube or venous blood can be collected by attaching a safety Luer needle to the capillary tube.

  • +

    Why is there no Microvette® with a citrate preparation for coagulation?

    Capillary blood is not suitable for coagulation diagnostics. When collecting capillary blood, a certain amount of tissue fluid is also taken. This can result in false measurement values in coagulation analysis.

  • +

    Can the Microvette® be completely processed in automated analysers?

    There are special carrier tubes available (e.g. product no 55.1570; 55.1572;55.1571) which enable adaptation for analysis systems and centrifuges.There are special carrier tubes available (e.g. product no 55.1570; 55.1572;55.1571) which enable adaptation for analysis systems and centrifuges.

  • +

    Which drawing techniques can be used to collect capillary blood with the Microvette®?

    When using the Microvette®, the user has a choice of two collection techniques. The blood can either be taken using the pre-assembled end-to-end capillary or with the special rim. 

  • +

    Does it have an expiry date and, if yes, where can it be found?

    Yes, each Microvette® is labelled with an expiry date and lot number.

  • +

    Which centrifugation conditions must be taken into account for the Microvette® and Multivette® with serum preparation?

    For serum, the optimal conditions are 5 minutes, 10,000 x g at 20°C. The recommended centrifugation conditions are printed on the labels of each inner box and are found on the Sarstedt website under Product Specifications.

  • +

    What centrifugation conditions must be taken into account for the Microvette® and Multivette® with serum gel and lithium heparin gel preparations?

    For serum gel and lithium heparin gel, the optimal conditions are 5 minutes, 10,000 x g at 20°C. The recommended centrifugation conditions are printed on the labels of each inner box and can be found on the Sarstedt website under Product Specifications.

  • +

    What centrifugation conditions must be taken into account for the Microvette® and Multivette® with lithium heparin, fluoride and EDTA?

    For lithium heparin, EDTA and fluoride, the optimal conditions are 5 minutes, 2000 x g at 20°C. The recommended centrifugation conditions are printed on the labels of each inner box and can be found on the Sarstedt website under Product Specifications.

  • +

    Can the Microvette® also be used for venous blood collection?

    The Microvette® has the ideal features for capillary blood collection, but it can also be used for venous blood collection. Alternatively, the prepared micro sample tubes with attached lid or screw cap can be used. These are ideal for venous blood collection.

  • +

    Which capillary system can be used to determine ESR?

    The Microvette® CB 200 ESR (product no 18.1325) is ideal for measuring blood sedimentation from capillary blood.

  • +

    Why are there Microvettes with conical and cylindrical inner tubes?

    Microvettes with conical inner tubes provide optimum pipetting of serum and plasma supernatants, even with small amounts of blood. The cylindrical inner tube makes it easier to mix the sample and enables optimal gel separation after centrifugation.

  • +

    In what order should capillary blood draws be taken?

    The CLSI standard (Clinical and Laboratory Standards Institute) recommends EDTA, heparin, heparin gel, fluoride, serum and then serum gel.