Microvette® APT Automated Processing Tube
Microvette® APT Automated Processing Tube
Language:
Different patient groups and collection techniques require different collection systems. With a nominal volume range from 100–600 µl, the capillary blood collection systems product range is one of the most extensive in the entire market. Depending on the requirements, our portfolio includes Microvettes with conical or round bottom inner tubes and the option for various different collection techniques, end-to-end or with a collection rim.
Microvette® CB 200 NC, capillary blood collection, preparation: Trisodium citrate solution (1:4), nominal volume: 200 µl, (LxØ) with cap: 46 x 10.8 mm, cap black, push cap, flat base, incl. sedimentation pipette, 50 piece(s)/bag
Microvette® APT 250 EDTA K2E, capillary blood collection, preparation: K2 EDTA, K2E, nominal volume: 250 µl, Ø: 13 mm, with plastic label, cap red, cap, with pierceable membrane, round base, inner receptacle: cylindrical, incl. quick-release cap, non-sterile, 50 piece(s)/case
Thrombo Plus®, for direct platelet counting, nominal volume: 2 ml, cap red, preparation: Hg salt, push cap, (LxØ): 75 x 11.5 mm, round base, with print, 50 piece(s)/case
End-to-end capillary, Ammonium heparin AH, capillary blood collection, preparation: Ammonium heparin, nominal volume: 10 µl, Ø: 1.25 mm, glass, 100 piece(s)/container
Blood gas capillaries, preparation: calcium-balanced lithium heparin, nominal volume: 125 µl, (LxØ): 110 x 2.05 mm, 250 piece(s)/container
Microvette® APT 500 EDTA K2E, capillary blood collection, preparation: K2 EDTA, nominal volume: 500 µl, Ø: 13 mm, with plastic label, cap violet, cap, with pierceable membrane, round base, inner receptacle: cylindrical, non-sterile, 100 piece(s)/case
Microvette® APT 250 EDTA K2E, capillary blood collection, preparation: K2 EDTA, K2E, nominal volume: 250 µl, Ø: 13 mm, with plastic label, cap violet, cap, with pierceable membrane, round base, inner receptacle: cylindrical, incl. quick-release cap, non-sterile, 50 piece(s)/case
Blood gas capillaries, preparation: calcium-balanced lithium heparin, nominal volume: 100 µl, (LxØ): 100 x 2.05 mm, 250 piece(s)/container
ESR rack, suitable for Microvette®, 10 measuring stations
Microvette® APT 500 EDTA K2E, capillary blood collection, preparation: K2 EDTA, K2E, nominal volume: 500 µl, Ø: 13 mm, with plastic label, cap red, cap, with pierceable membrane, round base, inner receptacle: cylindrical, non-sterile, 100 piece(s)/case
Blood gas capillaries, preparation: calcium-balanced lithium heparin, nominal volume: 140 µl, (LxØ): 75 x 2.3 mm, 200 piece(s)/container
Microvette® APT 250 EDTA K2E, capillary blood collection, preparation: K2 EDTA, K2E, nominal volume: 250 µl, Ø: 13 mm, cap violet, cap, with pierceable membrane, round base, inner receptacle: cylindrical, incl. quick-release cap, non-sterile, 50 piece(s)/case
Microvette® 500 EDTA K2E, capillary blood collection, preparation: K2 EDTA, nominal volume: 500 µl, (LxØ) with cap: 47.6 x 10.8 mm, with print, cap violet, flat base, inner receptacle: cylindrical, 100 piece(s)/case
Microvette® CB 200 NC, capillary blood collection, preparation: Trisodium citrate solution (1:4), nominal volume: 200 µl, (LxØ) with cap: 46 x 10.8 mm, cap violet, push cap, flat base, incl. sedimentation pipette, 50 piece(s)/bag
Microvette® APT 500 EDTA K2E, capillary blood collection, preparation: K2 EDTA, K2E, nominal volume: 500 µl, Ø: 13 mm, with plastic label, cap violet, cap, with pierceable membrane, round base, inner receptacle: cylindrical, non-sterile, 100 piece(s)/case
Blood gas capillaries, preparation: calcium-balanced lithium heparin, nominal volume: 175 µl, (LxØ): 100 x 2.3 mm, 200 piece(s)/container
End-to-end capillary, K2 EDTA, capillary blood collection, preparation: K2 EDTA, nominal volume: 20 µl, Ø: 1.28 mm, glass, 100 piece(s)/container
Microvette® 500 EDTA K3E, low lead, capillary blood collection, preparation: K3 EDTA, nominal volume: 500 µl, (LxØ) with cap: 47.6 x 10.8 mm, with print, cap violet, flat base, inner receptacle: cylindrical, 100 piece(s)/case
Microvette® 500 Serum CAT, capillary blood collection, preparation: clotting activator, nominal volume: 500 µl, (LxØ) with cap: 47.6 x 10.8 mm, with print, cap white, flat base, inner receptacle: cylindrical, 100 piece(s)/case
Microvette® 300 Serum CAT, capillary blood collection, preparation: clotting activator, nominal volume: 300 µl, (LxØ) with cap: 47.6 x 10.8 mm, with print, cap white, flat base, inner receptacle: conical, 100 piece(s)/case
Microvette® 200 Serum CAT, capillary blood collection, preparation: clotting activator, nominal volume: 200 µl, (LxØ) with cap: 47.6 x 10.8 mm, with print, cap white, flat base, inner receptacle: conical, 100 piece(s)/case
Microvette® 100 Serum CAT, capillary blood collection, preparation: clotting activator, nominal volume: 100 µl, (LxØ) with cap: 47.6 x 10.8 mm, with print, cap white, flat base, inner receptacle: conical, 100 piece(s)/case
Microvette® 500 Serum Gel CAT, capillary blood collection, preparation: Clotting activator/gel, nominal volume: 500 µl, (LxØ) with cap: 47.6 x 10.8 mm, with print, cap brown, flat base, inner receptacle: cylindrical, 100 piece(s)/case
Microvette® 200 Serum Gel CAT, capillary blood collection, preparation: Clotting activator/gel, nominal volume: 200 µl, (LxØ) with cap: 47.6 x 10.8 mm, with print, cap brown, flat base, inner receptacle: cylindrical, 100 piece(s)/case
Microvette® 500 Lithium heparin LH, capillary blood collection, preparation: lithium heparin LH, nominal volume: 500 µl, (LxØ) with cap: 47.6 x 10.8 mm, with print, cap orange, flat base, inner receptacle: cylindrical, 100 piece(s)/case
Microvette® 300 Lithium heparin LH, capillary blood collection, preparation: lithium heparin LH, nominal volume: 300 µl, (LxØ) with cap: 47.6 x 10.8 mm, with print, cap orange, flat base, inner receptacle: conical, 100 piece(s)/case
Microvette® 200 Lithium heparin LH, capillary blood collection, preparation: lithium heparin LH, nominal volume: 200 µl, (LxØ) with cap: 47.6 x 10.8 mm, with print, cap orange, flat base, inner receptacle: conical, 100 piece(s)/case
Microvette® 100 Lithium heparin LH, capillary blood collection, preparation: lithium heparin LH, nominal volume: 100 µl, (LxØ) with cap: 47.6 x 10.8 mm, with print, cap orange, flat base, inner receptacle: conical, 100 piece(s)/case
Microvette® 500 Lithium heparin gel LH, capillary blood collection, preparation: Lithium heparin gel, nominal volume: 500 µl, (LxØ) with cap: 47.6 x 10.8 mm, with print, cap orange, flat base, inner receptacle: cylindrical, 100 piece(s)/case
Microvette® 500 EDTA K3E, capillary blood collection, preparation: K3 EDTA, nominal volume: 500 µl, (LxØ) with cap: 47.6 x 10.8 mm, with print, cap red, flat base, inner receptacle: cylindrical, 100 piece(s)/case
Microvette® 200 EDTA K3E, capillary blood collection, preparation: K3 EDTA, nominal volume: 200 µl, (LxØ) with cap: 47.6 x 10.8 mm, with print, cap red, flat base, inner receptacle: cylindrical, 100 piece(s)/case
Microvette® 100 EDTA K3E, capillary blood collection, preparation: K3 EDTA, nominal volume: 100 µl, (LxØ) with cap: 47.6 x 10.8 mm, with print, cap red, flat base, inner receptacle: cylindrical, 100 piece(s)/case
Microvette® 300 Fluoride/heparin FH, capillary blood collection, preparation: Fluoride + heparin, nominal volume: 300 µl, (LxØ) with cap: 47.6 x 10.8 mm, with print, cap yellow, flat base, inner receptacle: conical, 100 piece(s)/case
Microvette® 200 Fluoride/heparin FH, capillary blood collection, preparation: Fluoride + heparin, nominal volume: 200 µl, (LxØ) with cap: 47.6 x 10.8 mm, with print, cap yellow, flat base, inner receptacle: conical, 100 piece(s)/case
Microvette® 500 Serum CAT, capillary blood collection, preparation: clotting activator, nominal volume: 500 µl, (LxØ) with cap: 47.6 x 10.8 mm, with print, cap red, flat base, inner receptacle: cylindrical, 100 piece(s)/case
Microvette® 300 Serum CAT, capillary blood collection, preparation: clotting activator, nominal volume: 300 µl, (LxØ) with cap: 47.6 x 10.8 mm, with print, cap red, flat base, inner receptacle: conical, 100 piece(s)/case
Microvette® 200 Serum CAT, capillary blood collection, preparation: clotting activator, nominal volume: 200 µl, (LxØ) with cap: 47.6 x 10.8 mm, with print, cap red, flat base, inner receptacle: conical, 100 piece(s)/case
Microvette® 100 Serum CAT, capillary blood collection, preparation: clotting activator, nominal volume: 100 µl, (LxØ) with cap: 47.6 x 10.8 mm, with print, cap red, flat base, inner receptacle: conical, 100 piece(s)/case
Microvette® 500 Lithium heparin LH, capillary blood collection, preparation: lithium heparin LH, nominal volume: 500 µl, (LxØ) with cap: 47.6 x 10.8 mm, with print, cap green, flat base, inner receptacle: cylindrical, 100 piece(s)/case
Microvette® 300 Lithium heparin LH, capillary blood collection, preparation: lithium heparin LH, nominal volume: 300 µl, (LxØ) with cap: 47.6 x 10.8 mm, with print, cap green, flat base, inner receptacle: conical, 100 piece(s)/case
Microvette® 200 Lithium heparin LH, capillary blood collection, preparation: lithium heparin LH, nominal volume: 200 µl, (LxØ) with cap: 47.6 x 10.8 mm, with print, cap green, flat base, inner receptacle: conical, 100 piece(s)/case
Microvette® 100 Lithium heparin LH, capillary blood collection, preparation: lithium heparin LH, nominal volume: 100 µl, (LxØ) with cap: 47.6 x 10.8 mm, with print, cap green, flat base, inner receptacle: conical, 100 piece(s)/case
Microvette® 500 Lithium heparin gel LH, capillary blood collection, preparation: Lithium heparin gel, nominal volume: 500 µl, (LxØ) with cap: 47.6 x 10.8 mm, with print, cap green, flat base, inner receptacle: cylindrical, 100 piece(s)/case
Microvette® 500 EDTA K3E, capillary blood collection, preparation: K3 EDTA, nominal volume: 500 µl, (LxØ) with cap: 47.6 x 10.8 mm, with print, cap violet, flat base, inner receptacle: cylindrical, 100 piece(s)/case
Microvette® 200 EDTA K3E, capillary blood collection, preparation: K3 EDTA, nominal volume: 200 µl, (LxØ) with cap: 47.6 x 10.8 mm, with print, cap violet, flat base, inner receptacle: cylindrical, 100 piece(s)/case
Microvette® 100 EDTA K3E, capillary blood collection, preparation: K3 EDTA, nominal volume: 100 µl, (LxØ) with cap: 47.6 x 10.8 mm, with print, cap violet, flat base, inner receptacle: cylindrical, 100 piece(s)/case
Microvette® 300 Fluoride/heparin FH, capillary blood collection, preparation: Fluoride + heparin, nominal volume: 300 µl, (LxØ) with cap: 47.6 x 10.8 mm, with print, cap grey, flat base, inner receptacle: conical, 100 piece(s)/case
Microvette® 200 Fluoride/heparin FH, capillary blood collection, preparation: Fluoride + heparin, nominal volume: 200 µl, (LxØ) with cap: 47.6 x 10.8 mm, with print, cap grey, flat base, inner receptacle: conical, 100 piece(s)/case
Minivette® POCT neutral Z, nominal volume: 200 µl, without preparation, white, 150 piece(s)/bag, 150 piece(s)/case
Minivette® POCT neutral Z, nominal volume: 100 µl, without preparation, white, 200 piece(s)/bag, 200 piece(s)/case
Minivette® POCT neutral Z, nominal volume: 50 µl, without preparation, white, 200 piece(s)/bag, 200 piece(s)/case
Minivette® POCT neutral Z, nominal volume: 20 µl, without preparation, white, 200 piece(s)/bag, 200 piece(s)/case
Minivette® POCT neutral Z, nominal volume: 10 µl, without preparation, white, 200 piece(s)/bag, 200 piece(s)/case
Minivette® POCT Lithium heparin LH, nominal volume: 200 µl, preparation: Heparin, orange, colour code EU, 150 piece(s)/bag, 150 piece(s)/case
Minivette® POCT Lithium heparin LH, nominal volume: 100 µl, preparation: Heparin, orange, colour code EU, 200 piece(s)/bag, 200 piece(s)/case
Minivette® POCT Lithium heparin LH, nominal volume: 50 µl, preparation: Heparin, orange, colour code EU, 200 piece(s)/bag, 200 piece(s)/case
Minivette® POCT Lithium heparin LH, nominal volume: 20 µl, preparation: Heparin, orange, colour code EU, 200 piece(s)/bag, 200 piece(s)/case
Minivette® POCT EDTA K3E, nominal volume: 50 µl, preparation: K3 EDTA, red, colour code EU, 200 piece(s)/bag, 200 piece(s)/case
Minivette® POCT EDTA K3E, nominal volume: 20 µl, preparation: K3 EDTA, red, colour code EU, 200 piece(s)/bag, 200 piece(s)/case
Minivette® POCT Lithium heparin LH, nominal volume: 200 µl, preparation: Heparin, green, colour code ISO, 150 piece(s)/bag, 150 piece(s)/case
Minivette® POCT Lithium heparin LH, nominal volume: 100 µl, preparation: Heparin, green, colour code ISO, 200 piece(s)/bag, 200 piece(s)/case
Minivette® POCT Lithium heparin LH, nominal volume: 50 µl, preparation: Heparin, green, colour code ISO, 200 piece(s)/bag, 200 piece(s)/case
Minivette® POCT Lithium heparin LH, nominal volume: 20 µl, preparation: Heparin, green, colour code ISO, 200 piece(s)/bag, 200 piece(s)/case
Minivette® POCT EDTA K3E, nominal volume: 50 µl, preparation: K3 EDTA, violet, colour code ISO, 200 piece(s)/bag, 200 piece(s)/case
Minivette® POCT EDTA K3E, nominal volume: 20 µl, preparation: K3 EDTA, violet, colour code ISO, 200 piece(s)/bag, 200 piece(s)/case
Minivette® POCT EDTA K3E, nominal volume: 100 µl, preparation: K3 EDTA, violet, colour code ISO, 200 piece(s)/bag, 200 piece(s)/case
Minivette® POCT EDTA K3E, nominal volume: 200 µl, preparation: K3 EDTA, violet, colour code ISO, 150 piece(s)/bag, 150 piece(s)/case
Multivette® 600 Serum CAT, venous and capillary blood samples, preparation: clotting activator, nominal volume: 600 µl, (LxØ) with cap: 47.9 x 8 mm, with print, cap white, screw cap, flat base, 100 piece(s)/case
Multivette® 600 Serum Gel CAT, venous and capillary blood samples, preparation: Clotting activator/gel, nominal volume: 600 µl, (LxØ) with cap: 53.3 x 8 mm, with print, cap brown, screw cap, flat base, 100 piece(s)/case
Multivette® 600 Lithium heparin LH, venous and capillary blood samples, preparation: lithium heparin LH, nominal volume: 600 µl, (LxØ) with cap: 47.9 x 8 mm, with print, cap orange, screw cap, flat base, 100 piece(s)/case
Multivette® 600 Lithium heparin gel LH, venous and capillary blood samples, preparation: Lithium heparin gel, nominal volume: 600 µl, (LxØ) with cap: 53.3 x 8 mm, with print, cap orange, screw cap, flat base, 100 piece(s)/case
Multivette® 600 EDTA K3E, venous and capillary blood samples, preparation: K3 EDTA, nominal volume: 600 µl, (LxØ) with cap: 47.9 x 8 mm, with print, cap red, screw cap, flat base, 100 piece(s)/case
Multivette® 600 Fluoride/heparin FH, venous and capillary blood samples, preparation: Fluoride + heparin, nominal volume: 600 µl, (LxØ) with cap: 47.9 x 8 mm, with print, cap yellow, screw cap, flat base, 100 piece(s)/case
Multivette® 600 Serum CAT, venous and capillary blood samples, preparation: clotting activator, nominal volume: 600 µl, (LxØ) with cap: 47.9 x 8 mm, with print, cap red, screw cap, flat base, 100 piece(s)/case
Multivette® 600 Lithium heparin LH, venous and capillary blood samples, preparation: lithium heparin LH, nominal volume: 600 µl, (LxØ) with cap: 47.9 x 8 mm, with print, cap green, screw cap, flat base, 100 piece(s)/case
Multivette® 600 Lithium heparin gel LH, venous and capillary blood samples, preparation: Lithium heparin gel, nominal volume: 600 µl, (LxØ) with cap: 53.3 x 8 mm, with print, cap green, screw cap, flat base, 100 piece(s)/case
Multivette® 600 EDTA K3E, venous and capillary blood samples, preparation: K3 EDTA, nominal volume: 600 µl, (LxØ) with cap: 47.9 x 8 mm, with print, cap violet, screw cap, flat base, 100 piece(s)/case
Microvette® CB 300 Serum CAT, capillary blood collection, preparation: clotting activator, nominal volume: 300 µl, (LxØ) with cap: 46.5 x 10.8 mm, cap white, push cap, flat base, inner receptacle: trumpet-shaped, 100 piece(s)/bag
Microvette® CB 300 Lithium heparin LH, capillary blood collection, preparation: lithium heparin LH, nominal volume: 300 µl, (LxØ) with cap: 46.5 x 10.8 mm, cap orange, push cap, flat base, inner receptacle: trumpet-shaped, 100 piece(s)/bag
Microvette® CB 300 Lithium heparin LH, capillary blood collection, preparation: lithium heparin LH, nominal volume: 300 µl, (LxØ) with cap: 46.5 x 10.8 mm, cap orange, push cap, flat base, inner receptacle: trumpet-shaped, carrier tube: brown, 100 piece(s)/bag
Microvette® CB 300 EDTA K2E, capillary blood collection, preparation: K2 EDTA, nominal volume: 300 µl, (LxØ) with cap: 46.5 x 10.8 mm, cap red, push cap, flat base, inner receptacle: trumpet-shaped, 100 piece(s)/bag
Microvette® CB 300 Fluoride/heparin FH, capillary blood collection, preparation: Fluoride + heparin, nominal volume: 300 µl, (LxØ) with cap: 46.5 x 10.8 mm, cap yellow, push cap, flat base, inner receptacle: trumpet-shaped, 100 piece(s)/bag
Microvette® CB 300 Serum CAT, capillary blood collection, preparation: clotting activator, nominal volume: 300 µl, (LxØ) with cap: 46.5 x 10.8 mm, cap red, push cap, flat base, inner receptacle: trumpet-shaped, 100 piece(s)/bag
Microvette® CB 300 Lithium heparin LH, capillary blood collection, preparation: lithium heparin LH, nominal volume: 300 µl, (LxØ) with cap: 46.5 x 10.8 mm, cap green, push cap, flat base, inner receptacle: trumpet-shaped, 100 piece(s)/bag
Microvette® CB 300 EDTA K2E, capillary blood collection, preparation: K2 EDTA, nominal volume: 300 µl, (LxØ) with cap: 46.5 x 10.8 mm, cap violet, push cap, flat base, inner receptacle: trumpet-shaped, 100 piece(s)/bag
Micro sample tube, 1.000 µl haemolysis solution/20 µl, capillary blood collection, preparation: SARSTEDT haemolysis solution, incl. 20 µl end-to-end capillary, nominal volume: 20 µl, (LxØ) with cap: 42 x 10.8 mm, cap: yellow, label/print: black, push cap, conical base, 1, 100 piece(s)/bag
Micro sample tube, 1,000 µl DiaSys/20 µl, capillary blood collection, preparation: DiaSys haemolysis solution, incl. 20 µl end-to-end capillary, nominal volume: 20 µl, (LxØ) with cap: 42 x 10.8 mm, cap: white, label/print: black, push cap, conical base, 1, 100 piece(s)/bag
Micro sample tube, 500 µl Roche-Gen. 2/20 µl, capillary blood collection, preparation: Roche haemolysis gen. 2, incl. 20 µl end-to-end capillary, nominal volume: 20 µl, (LxØ) with cap: 42 x 10.8 mm, cap: white, push cap, skirted conical base, 2, 100 piece(s)/bag
Micro sample tube, 1,000 µl ESAT/20µl, capillary blood collection, preparation: ESAT haemolysis solution, incl. 20 µl end-to-end capillary, nominal volume: 20 µl, (LxØ) with cap: 42 x 10.8 mm, cap: yellow, push cap, skirted conical base, 2, 100 piece(s)/bag
Sample tube, Blood sugar determination from capillary blood, nominal volume: 1,000 µl, cap white, preparation: SARSTEDT haemolysis solution, screw cap, (LxØ): 97 x 15.3 mm, conical false bottom, rounded tube bottom, with print, 100 piece(s)/bag
Sample tube, HbA1c determination from capillary blood, nominal volume: 1,000 µl, cap black, preparation: Roche HbA1c haemolysis solution, screw cap, (LxØ): 82 x 11.5 mm, flat base, with paper label, 50 piece(s)/bag
Capillary holder, capillary blood collection, 5 piece(s)/bag
Micro sample tube 100 µl brillant, preparation: 1% brilliant cresyl blue solution, nominal volume: 100 µl, (LxØ) with cap: 46 x 10.8 mm, screw cap, cap: blue, conical base, 50 piece(s)/case
The Minivette® POCT is particularly suitable for the precise recovery and dispensing of defined small whole blood samples. This is especially required for Point-of-Care tests (POCT).
Both marks refer to the filling level. As the Multivette® is held horizontally and tilted slightly while collecting blood, the mark at the bottom of the Multivette® shows the correct filling level. After collection, the capillary tube is emptied through extraction. The filling level of an upright Multivette® can be read by the upper mark.
Both collection methods are possible with the Multivette®. The capillary tube has been developed so that either capillary blood can be collected directly with the self-filling capillary tube or venous blood can be collected by attaching a safety Luer needle to the capillary tube.
Capillary blood is not suitable for coagulation diagnostics. When collecting capillary blood, a certain amount of tissue fluid is also taken. This can result in false measurement values in coagulation analysis.
There are special carrier tubes available (e.g. product no 55.1570; 55.1572;55.1571) which enable adaptation for analysis systems and centrifuges.There are special carrier tubes available (e.g. product no 55.1570; 55.1572;55.1571) which enable adaptation for analysis systems and centrifuges.
When using the Microvette®, the user has a choice of two collection techniques. The blood can either be taken using the pre-assembled end-to-end capillary or with the special rim.
Yes, each Microvette® is labelled with an expiry date and lot number.
For serum, the optimal conditions are 5 minutes, 10,000 x g at 20°C. The recommended centrifugation conditions are printed on the labels of each inner box and are found on the Sarstedt website under Product Specifications.
For serum gel and lithium heparin gel, the optimal conditions are 5 minutes, 10,000 x g at 20°C. The recommended centrifugation conditions are printed on the labels of each inner box and can be found on the Sarstedt website under Product Specifications.
For lithium heparin, EDTA and fluoride, the optimal conditions are 5 minutes, 2000 x g at 20°C. The recommended centrifugation conditions are printed on the labels of each inner box and can be found on the Sarstedt website under Product Specifications.
The Microvette® has the ideal features for capillary blood collection, but it can also be used for venous blood collection. Alternatively, the prepared micro sample tubes with attached lid or screw cap can be used. These are ideal for venous blood collection.
The Microvette® CB 200 ESR (product no 18.1325) is ideal for measuring blood sedimentation from capillary blood.
Microvettes with conical inner tubes provide optimum pipetting of serum and plasma supernatants, even with small amounts of blood. The cylindrical inner tube makes it easier to mix the sample and enables optimal gel separation after centrifugation.
The CLSI standard (Clinical and Laboratory Standards Institute) recommends EDTA, heparin, heparin gel, fluoride, serum and then serum gel.