Product

Sediplus® S 2000 NX, automatic 40-channel blood sedimentation measuring device, incl. Test-Sedivettes for functional tests, 40 measuring stations, 110/230 V

Order number: 90.1092
Sediplus® S 2000 NX, automatic 40-channel blood sedimentation measuring device, incl. Test-Sedivettes for functional tests, 40 measuring stations, 110/230 V

Product description

Order number 90.1092
Product description Sediplus® S 2000 NX, automatic 40-channel blood sedimentation measuring device, incl. Test-Sedivettes for functional tests, suitable for S-Sedivette®, 40 measuring stations, for measuring the blood cell sedimentation rate (ESR), supply voltage: 110/230 V

Product characteristics

Application for measuring the blood cell sedimentation rate (ESR)
Suitable for S-Sedivette®
Number of positions 40
Interface HL7

Size

Width of product 270 mm
Height of product 305 mm
Length of product 355 mm

Purity & certification

Product category In vitrodiagnostic device, CE
CE certified CE
Batched no

Packaging

Minimum order qty. 1
Type of smallest subpackaging case
Piece(s) / inner box 1
Piece (s) / outer case 1
Piece(s) / pallet 1
Depth of case 510 mm
Width of case 430 mm
Height of case 350 mm
Case volume 0.0768 cbm
Weight of product 6.7 kg
Weight of case 9.2 kg
EAN of inner box 4038917927055
EAN case 4038917927062
Product specification

General

  • +

    Can the Sediplus® S 2000 NX ESR analyser be integrated into an existing LIS system?

    Yes, the Sediplus® S 2000 NX can be integrated through an interface.

  • +

    Do all the S-Sedivettes have to be placed in the Sediplus® device at the same time?

    No, each measuring station can be filled individually / independently of time.

  • +

    Is there an option to automatically determine ESR?

    Yes, the ESR can be determined automatically with the Sediplus® S 2000 NX (40 measuring stations).

  • +

    What must be taken into account when using the S-Sedivette® for blood sedimentation?

    For blood sedimentation, the S-Sedivette® should always be carefully mixed after blood collection. According to the CLSI standard, the measurement must be started no later than 4 hours after blood collection. The first reading of the blood sedimentation rate (ESR) should take place after 60 minutes. 

  • +

    How is the S-Sedivette® prepared?

    The S-Sedivette® is prepared with trisodium citrate solution, which is 20% of the nominal volume. This ensures the important ratio for blood sedimentation of 1 part citrate + 4 parts blood.

  • +

    What is the shelf life of the S-Sedivette®?

    The S-Sedivette® has a shelf life of 15 months.

  • +

    Does the S-Sedivette® have to be mixed after blood collection?

    Yes, the S-Sedivette® must be mixed thoroughly immediately after blood collection: invert the S-Sedivette® slowly five times. The air bubble / glass bead must always travel to the other end. Do not shake it back and forth quickly. For safety and to save time, we recommend the special Sarmix® M 2000 mixers.

  • +

    Are the values from the S-Sedivette® comparable to the Westergren method?

    The S-Sedivette® was developed and evaluated for determining the blood sedimentation rate (ESR) according to the Westergren method.