Sediplus® System Solutions
Sediplus® System Solutions

Language:
Order number | 18.1325.100 |
---|---|
Product description | Microvette® CB 200 NC, capillary blood collection, preparation: Trisodium citrate solution (1:4), nominal volume: 200 µl, (LxØ) with cap: 46 x 10.8 mm, cap black, push cap, flat base, incl. sedimentation pipette, 50 piece(s)/bag |
Type of collection | capillary |
---|---|
Type of preparation | Trisodium citrate solution (1:4) |
Colour code | ISO |
Closure type | push cap |
Application | capillary blood collection |
Base shape | flat base |
Sample volume | 200 µl |
---|---|
Diameter | 10.8 mm |
Length of product | 40 mm |
Length including cap | 46 mm |
Length excluding cap | 40 mm |
Product material | Polypropylene (PP) |
---|---|
Colour of product | transparent |
Closure material | Low Density Polyethylene (LD-PE) |
Colour of cap | black |
Product category | In-vitro diagnostic, CE |
---|---|
CE certified | CE |
Batched | yes |
Minimum order qty. | 15000 |
---|---|
Type of inner packaging | bag |
Piece(s) / inner box | 50 |
Piece(s) / case | 500 |
Piece(s) / pallet | 32000 |
Depth of box | 271 mm |
Width of box | 126 mm |
Height of box | 36 mm |
Depth of case | 283 mm |
Width of case | 268 mm |
Height of case | 210 mm |
Case volume | 0.0159 cbm |
Weight of product | 0.0036 kg |
Weight of case | 2.6 kg |
EAN of inner box | 4038917127653 |
EAN case | 4038917021333 |
Yes, the ESR analysers can be integrated through an interface.
No, each measuring station can be filled individually / independently of time.
Yes, ESR can be automatically determined with the Sediplus® S 200 (10 measuring stations) or the Sediplus® S 2000 (40 to 160 measuring stations).
In principle, for blood sedimentation the S-Sedivette® should be carefully mixed after blood collection. According to the CLSI standard, the measurement must be started at the latest 4–6 hours after blood collection. The first reading of the blood sedimentation rate (ESR) should take place after 60 minutes.
The S-Sedivette® is prepared with trisodium citrate solution, which is 20% of the nominal volume. This ensures the important ratio for blood sedimentation of 1 part citrate + 4 parts blood.
The S-Sedivette® has a shelf life of 15 months.
Yes, the S-Sedivette® must be mixed well immediately after blood collection: tilt the S-Sedivette® upside down carefully five times. The air bubble/glass bead must always travel right up to the end! Do not shake it quickly. The special mixing devices Sarmix® M 200 and Sarmix® M 2000 are recommended for safety and to save time.
The S-Sedivette® was developed and evaluated for determining the blood sedimentation rate (ESR) according to the Westergren method.