Product

Blood gas capillaries, calcium-balanced lithium heparin, 140 µl

Order number: 19.930.140
Blood gas capillaries, calcium-balanced lithium heparin, 140 µl

Product description

Order number 19.930.140
Product description Blood gas capillaries, preparation: calcium-balanced lithium heparin, nominal volume: 140 µl, (LxØ): 75 x 2.3 mm, 200 piece(s)/container

Product characteristics

Type of collection capillary
Type of preparation calcium-balanced lithium heparin
Preparation concentration 80 IU/ml blood
Application blood gas analysis

Size

Sample volume 140 µl
Diameter 2.3 mm
Length of product 75 mm

Material & colours

Product material Polyethylene therephthalate (PET)
Colour of product transparent

Purity & certification

Product category In vitrodiagnostic device, CE
CE certified CE
Latex-free yes
Batched yes

Packaging

Minimum order qty. 200
Type of smallest subpackaging container
Piece(s) / inner box 200
Piece (s) / outer case 12800
Piece(s) / pallet 921600
Depth of case 333 mm
Width of case 303 mm
Height of case 190 mm
Case volume 0.0192 cbm
Weight of product 0.0002 kg
Weight of case 4.22 kg
EAN of inner box 4038917234313
EAN case 4038917234306
Product specification

General

  • +

    Why does the excess air in a blood sample for blood gas analysis need to be removed immediately after blood collection?

    Generally, the oxygen or CO2 status is determined from the blood in a blood gas analysis. In order to do this, it is necessary to ensure that the blood sample is not enriched with oxygen from the excess air.

  • +

    Does Sarstedt offer collection systems for blood gas analytics?

    Yes, Sarstedt offers collection systems for arterial, venous (1 and 2 ml) and capillary (100 µl, 125 µl, 140 µl, 175 µl) sample collection. The Blood Gas Monovette® and the blood gas capillaries are prepared with Ca2+(calcium)-balanced heparin. 

  • +

    Is it possible to connect Safety-Needles/Safety-Multifly® needles to the Blood Gas Monovette®, which has a Luer connection, and collect blood?

    Yes, using the membrane adapter Art. No. 14.1112). This is placed on the Luer cone of the Blood Gas Monovette® and the procedure is then completed with the Safety-Needle/Safety-Multifly® needle as usual.

  • +

    Can the Blood Gas Monovette® be shaken well or swivelled to ensure that it is mixed well?

    No. Since the Blood Gas Monovette® which has been filled and has had the excess air removed does not have a dead volume, it is recommended that the blood sample is rolled carefully between the palms immediately after collection.

  • +

    How is the Blood Gas Monovette® prepared?

    The Blood Gas Monovette® is distinguished by its liquid preparation with Ca2+ -balanced heparin, which ensures rapid mixing of the heparin with the blood.

  • +

    What is Ca2+ -balanced/titrated/equilibrated heparin?

    In this heparin, all of the active binding sites are saturated with calcium, so Ca2+ can be determined from the blood sample without any interference.

  • +

    What needs to be taken into account when finishing blood collection with the Blood Gas Monovette® at a vascular access?

    At the end of the blood collection, the Blood Gas Monovette® should be twisted in a clockwise direction to remove it from the vascular access. The same applies to connecting and disconnecting to/from an analysis device.

  • +

    How long after blood collection can a blood gas analysis (BGA) be carried out on a blood sample which has not been chilled?

    The BGA should be carried out immediately if possible, but no later than 15 minutes after collection.

Go to top