Product

REGANESTH® Spinal needle pencil-point 25G x 90 mm

Order number: 79.8081.800
REGANESTH® Spinal needle pencil-point 25G x 90 mm

Product description

Order number 79.8081.800
Product description Spinal needle, pencil-point, 25G x 90 mm, connection: Luer (f)

Product characteristics

Application regional anaesthesia
Coding colour orange
Point sharpening pencil-point
Connection Luer (f)

Size

Diameter of needle (external) 25 G / 0,5 mm
Length of needle 90 mm

Purity & certification

Product category Medical device
CE certified CE0482 (Medcert)
Sterilisation Gas sterilisation
Batched yes

Packaging

Minimum order qty. 20
Piece(s) / inner box 20
Piece(s) / case 400
Piece(s) / pallet 19200
Depth of box 203 mm
Width of box 111 mm
Height of box 56 mm
Depth of case 464 mm
Width of case 313 mm
Height of case 220 mm
Case volume 0,032 cbm
Weight of product 0,0046 kg
Weight of case 2,93 kg
EAN of inner box 4028339111729
EAN case 4028339111712
Product specification

General

  • +

    Does a pencil-point tip reduce the post-puncture headache?

    The cause of the post-puncture headache is a loss of cerebrospinal fluid via the perforation site in the dura. The use of a needle which is as thin as possible coupled with the atraumatic shape of the pencil-point tip lead to very pronounced dural resistance and a very small puncture hole. This enables a significant reduction in the post-puncture headache.

  • +

    What is the relevance of a large diameter of the lateral opening on the needle tip?

    A large lateral eye diameter has no relevance. According to the fluid mechanics principle of the lowest possible cross section, a lateral opening adapted to the internal diameter leads to rapid cerebrospinal fluid return flow and optimal injection of the anaesthetic.

  • +

    Why are SARSTEDT spinal needles also available with a non-Luer connector?

    In the past few years, there have been several serious cases of incorrect administration of medication when carrying out regional anaesthesia, as a result of confusion regarding neuraxial and intravenous accesses.

    In order to protect patients against mix-ups in the future, the ISO 80369 series of standards has been developed. It recommends working with separate connectors even when carrying out regional anaesthesia.

    In order to meet these requirements for greater levels of patient safety, we are therefore offering with immediate effect regional anaesthesia instruments and accessories with NRFitTM Non-Luer connectors, which significantly decrease the occurrence of incidents caused by the accidental use of incorrect medication in the case of intravenous applications and neuraxial blockade techniques.

    The NRFitTM Non-Luer connector is a connector designed specifically for regional anaesthesia which is characterised by its incompatibility with Luer connectors, although it is based on the functional principle of the Luer connector. This enables a convenient change of system without laborious adaptation to a new handling technique.

    You can not only identify the NRFitTM products from the relevant logo but also from yellow markings on the packaging and the products themselves. This means they can be quickly differentiated from other products and identified as part of the regional anaesthesia.

  • +

    How are the needle sizes defined by gauge sizes?

    Gauge is a description and measurement unit of the width or the outer diameter of needles and tubes. The number of the gauge is reciprocal to the diameter, in other words the higher the G, the lower the diameter.  The conversion to millimetres, the external diameter and colour coding is standardised in EN ISO 6009 and EN ISO 9626.

  • +

    Why are SARSTEDT spinal needles also available with a Non-Luer connector?

    In the past few years, there have been several serious cases of incorrect administration of medication when carrying out local anaesthesia, as a result of confusion regarding neuraxial and intravenous accesses.

    In order to protect patients against mix-ups in the future, the ISO 80369 series of standards has been developed. It recommends working with separate connectors even when carrying out local anaesthesia.

    In order to meet these requirements for greater levels of patient safety, we are therefore now offering local anaesthesia instruments and accessories with NRFitTM Non-Luer connectors, which significantly decrease the occurrence of incidents caused by the accidental use of incorrect medication in the case of intravenous applications and neuraxial blockade techniques.

    The NRFitTM Non-Luer connector is a connector designed specifically for local anaesthesia, which is characterised by its incompatibility with Luer connectors, although it is based on the functional principle of the Luer connector. This enables users to change system conveniently without laborious adaptation to a new handling technique.

    You can not only identify the NRFitTM products from the relevant logo but also from yellow markings on the packaging and the products themselves. This means they can be quickly differentiated from other products and identified as part of the local anaesthesia.

Go to top